Morimoto Y, Doi
K, Kobatake R, Wakamatsu K, Izumikawa T, Oki Y, Tsuga K. Reliability of
drilling torque values measured with a novel measurement drill for guiding
implant placement protocols. J Clin Exp Dent. 2025;17(10):e1230-4.
doi:10.4317/jced.63175
https://doi.org/10.4317/jced.63175
___
References
1.
Astrand P, Billström C, Feldmann H, Fischer K, Henricsson V, Johansson B, et
al. Tapered implants in jaws with soft bone quality: a clinical and
radiographic 1-year study of the Brånemark System Mark IV fixture. Clin
Implant Dent Relat Res. 2003;5(4):213-218. |
|
|
|
2.
Turkyilmaz I, Sennerby L, McGlumphy EA, Tözüm TF. Biomechanical aspects of
primary implant stability: a human cadaver study. Clin Implant Dent Relat
Res. 2009;11(2):113-119. |
|
|
|
3.
Oue H, Doi K, Oki Y, Makihara Y, Kubo T, Perrotti V, et al. Influence of
implant surface topography on primary stability in a standardized
osteoporosis rabbit model study. J Funct Biomater. 2015;6(1):143-152. |
|
|
|
4.
Yang B, Irastorza-Landa A, Heuberger P, Ploeg HL. Effect of insertion factors
on dental implant insertion torque/energy-experimental results. J Mech Behav
Biomed Mater. 2020;112:103995. |
|
|
|
5.
Eriksson AR, Albrektsson T. Temperature threshold levels for heat-induced
bone tissue injury: a vital-microscopic study in the rabbit. J Prosthet Dent.
1983;50(1):101-107. |
|
|
|
6.
Alghamdi H, Anand PS, Anil S. Undersized implant site preparation to enhance
primary implant stability in poor bone density: a prospective clinical study.
J Oral Maxillofac Surg. 2011;69(12):e506-512. |
|
|
|
7.
Friberg B, Ekestubbe A, Mellström D, Sennerby L. Brånemark implants and
osteoporosis: a clinical exploratory study. Clin Implant Dent Relat Res.
2001;3(1):50-56. |
|
|
|
8.
Shokri A, Ghanbari M, Maleki FH, Ramezani L, Amini P, Tapak L. Relationship
of gray values in cone beam computed tomography and bone mineral density
obtained by dual energy X-ray absorptiometry. Oral Surg Oral Med Oral Pathol
Oral Radiol. 2019;128(3):319-331. |
|
|
|
9.
Bruno V, Berti C, Barausse C, Badino M, Gasparro R, Ippolito DR, Felice P.
Clinical relevance of bone density values from CT related to dental implant
stability: a retrospective study. Biomed Res Int. 2018;2018:6758245. |
|
|
|
10.
Rokn AR, Labibzadeh A, Ghohroudi AAR, Shamshiri AR, Solhjoo S.
Histomorphometric analysis of bone density in relation to tactile sense of
the surgeon during dental implant placement. Open Dent J. 2018;12:46-52. |
|
|
|
11.
Wakamatsu K, Doi K, Kobatake R, Oki Y, Tsuga K. Evaluation of bone density
for primary implant stability using a newly designed drill: an in vitro study
on polyurethane bone blocks. Clin Exp Dent Res. 2024;10(6):e70048. |
|
|
|
12.
Doi K, Wakamatsu K, Kobatake R, Oki Y, Makihara Y, Konishi M, et al.
Usefulness of a novel density measurement drill for evaluating cancellous
bone density: correlation between CT value and drilling torque value in
bovine ribs. Int J Implant Dent. 2025;11(1):7. |
|
|
|
13.
Misch CE. Density of bone: effect on treatment plans, surgical approach,
healing, and progressive boen loading. Int J Oral Implantol. 1990;6(2):23-31. PMid:2073394 |
|
|
|
14.
Hong J, Lim YJ, Park SO. Quantitative biomechanical analysis of the influence
of the cortical bone and implant length on primary stability. Clin Oral
Implants Res. 2012;23(10):1193-1197. |
|
|
|
15.
Jimbo R, Tovar N, Anchieta RB, Machado LS, Marin C, Teixeira HS, et al. The
combined effects of undersized drilling and implant macrogeometry on bone
healing around dental implants: an experimental study. Int J Oral Maxillofac
Surg. 2014;43(10):1269-1275. |
|
|
|
16.
Alghamdi H, Anand PS, Anil S. Undersized implant site preparation to enhance
primary implant stability in poor bone density: a prospective clinical study.
J Oral Maxillofac Surg. 2011;69(12):e506-512. |
|
|
|
17.
Goswami MM, Kumar M, Vats A, Bansal AS. Evaluation of dental implant
insertion torque using a manual ratchet. Med J Armed Forces India.
2015;71(Suppl 2):S327-332. |
|
|
|
18.
Douglas de Oliveira DW, Lages FS, Lanza LA, Gomes AM, Queiroz TP, Costa Fde
O. Dental implants with immediate loading using insertion torque of 30 ncm: a
systematic review. Implant Dent. 2016;25(5):675-683. |
|
|
|
19.
Barone A, Alfonsi F, Derchi G, Tonelli P, Toti P, Marchionni S, et al. The
effect of insertion torque on the clinical outcome of single implants: a
randomized clinical trial. Clin Implant Dent Relat Res. 2016;18(3):588-600. |
|
|
|
20.
Degidi M, Daprile G, Piattelli A. Influence of underpreparation on primary
stability of implants inserted in poor quality bone sites: an in vitro study.
J Oral Maxillofac Surg. 2015;73(6):1084-1088. |