Morimoto Y, Doi K, Kobatake R, Wakamatsu K, Izumikawa T, Oki Y, Tsuga K. Reliability of drilling torque values measured with a novel measurement drill for guiding implant placement protocols. J Clin Exp Dent. 2025;17(10):e1230-4.

 

doi:10.4317/jced.63175

https://doi.org/10.4317/jced.63175

___

 

References

1. Astrand P, Billström C, Feldmann H, Fischer K, Henricsson V, Johansson B, et al. Tapered implants in jaws with soft bone quality: a clinical and radiographic 1-year study of the Brånemark System Mark IV fixture. Clin Implant Dent Relat Res. 2003;5(4):213-218.
https://doi.org/10.1111/j.1708-8208.2003.tb00203.x
PMid:15127991

 

2. Turkyilmaz I, Sennerby L, McGlumphy EA, Tözüm TF. Biomechanical aspects of primary implant stability: a human cadaver study. Clin Implant Dent Relat Res. 2009;11(2):113-119.
https://doi.org/10.1111/j.1708-8208.2008.00097.x
PMid:18422713

 

3. Oue H, Doi K, Oki Y, Makihara Y, Kubo T, Perrotti V, et al. Influence of implant surface topography on primary stability in a standardized osteoporosis rabbit model study. J Funct Biomater. 2015;6(1):143-152.
https://doi.org/10.3390/jfb6010143
PMid:25794350 PMCid:PMC4384105

 

4. Yang B, Irastorza-Landa A, Heuberger P, Ploeg HL. Effect of insertion factors on dental implant insertion torque/energy-experimental results. J Mech Behav Biomed Mater. 2020;112:103995.
https://doi.org/10.1016/j.jmbbm.2020.103995
PMid:32882675

 

5. Eriksson AR, Albrektsson T. Temperature threshold levels for heat-induced bone tissue injury: a vital-microscopic study in the rabbit. J Prosthet Dent. 1983;50(1):101-107.
https://doi.org/10.1016/0022-3913(83)90174-9
PMid:6576145

 

6. Alghamdi H, Anand PS, Anil S. Undersized implant site preparation to enhance primary implant stability in poor bone density: a prospective clinical study. J Oral Maxillofac Surg. 2011;69(12):e506-512.
https://doi.org/10.1016/j.joms.2011.08.007
PMid:22117707

 

7. Friberg B, Ekestubbe A, Mellström D, Sennerby L. Brånemark implants and osteoporosis: a clinical exploratory study. Clin Implant Dent Relat Res. 2001;3(1):50-56.
https://doi.org/10.1111/j.1708-8208.2001.tb00128.x
PMid:11441543

 

8. Shokri A, Ghanbari M, Maleki FH, Ramezani L, Amini P, Tapak L. Relationship of gray values in cone beam computed tomography and bone mineral density obtained by dual energy X-ray absorptiometry. Oral Surg Oral Med Oral Pathol Oral Radiol. 2019;128(3):319-331.
https://doi.org/10.1016/j.oooo.2019.04.017
PMid:31171482

 

9. Bruno V, Berti C, Barausse C, Badino M, Gasparro R, Ippolito DR, Felice P. Clinical relevance of bone density values from CT related to dental implant stability: a retrospective study. Biomed Res Int. 2018;2018:6758245.
https://doi.org/10.1155/2018/6758245
PMid:29955608 PMCid:PMC6000841

 

10. Rokn AR, Labibzadeh A, Ghohroudi AAR, Shamshiri AR, Solhjoo S. Histomorphometric analysis of bone density in relation to tactile sense of the surgeon during dental implant placement. Open Dent J. 2018;12:46-52.
https://doi.org/10.2174/1874210601812010046
PMid:29492168 PMCid:PMC5814951

 

11. Wakamatsu K, Doi K, Kobatake R, Oki Y, Tsuga K. Evaluation of bone density for primary implant stability using a newly designed drill: an in vitro study on polyurethane bone blocks. Clin Exp Dent Res. 2024;10(6):e70048.
https://doi.org/10.1002/cre2.70048
PMid:39610027 PMCid:PMC11604594

 

12. Doi K, Wakamatsu K, Kobatake R, Oki Y, Makihara Y, Konishi M, et al. Usefulness of a novel density measurement drill for evaluating cancellous bone density: correlation between CT value and drilling torque value in bovine ribs. Int J Implant Dent. 2025;11(1):7.
https://doi.org/10.1186/s40729-025-00596-9
PMid:39888340 PMCid:PMC11785876

 

13. Misch CE. Density of bone: effect on treatment plans, surgical approach, healing, and progressive boen loading. Int J Oral Implantol. 1990;6(2):23-31.

PMid:2073394

 

14. Hong J, Lim YJ, Park SO. Quantitative biomechanical analysis of the influence of the cortical bone and implant length on primary stability. Clin Oral Implants Res. 2012;23(10):1193-1197.
https://doi.org/10.1111/j.1600-0501.2011.02285.x
PMid:22092387

 

15. Jimbo R, Tovar N, Anchieta RB, Machado LS, Marin C, Teixeira HS, et al. The combined effects of undersized drilling and implant macrogeometry on bone healing around dental implants: an experimental study. Int J Oral Maxillofac Surg. 2014;43(10):1269-1275.
https://doi.org/10.1016/j.ijom.2014.03.017
PMid:24794761

 

16. Alghamdi H, Anand PS, Anil S. Undersized implant site preparation to enhance primary implant stability in poor bone density: a prospective clinical study. J Oral Maxillofac Surg. 2011;69(12):e506-512.
https://doi.org/10.1016/j.joms.2011.08.007
PMid:22117707

 

17. Goswami MM, Kumar M, Vats A, Bansal AS. Evaluation of dental implant insertion torque using a manual ratchet. Med J Armed Forces India. 2015;71(Suppl 2):S327-332.
https://doi.org/10.1016/j.mjafi.2013.07.010
PMid:26843747 PMCid:PMC4705154

 

18. Douglas de Oliveira DW, Lages FS, Lanza LA, Gomes AM, Queiroz TP, Costa Fde O. Dental implants with immediate loading using insertion torque of 30 ncm: a systematic review. Implant Dent. 2016;25(5):675-683.
https://doi.org/10.1097/ID.0000000000000444
PMid:27540837

 

19. Barone A, Alfonsi F, Derchi G, Tonelli P, Toti P, Marchionni S, et al. The effect of insertion torque on the clinical outcome of single implants: a randomized clinical trial. Clin Implant Dent Relat Res. 2016;18(3):588-600.
https://doi.org/10.1111/cid.12337
PMid:26043651

 

20. Degidi M, Daprile G, Piattelli A. Influence of underpreparation on primary stability of implants inserted in poor quality bone sites: an in vitro study. J Oral Maxillofac Surg. 2015;73(6):1084-1088.
https://doi.org/10.1016/j.joms.2015.01.029
PMid:25861691