de Matos JDM, Lopes GRS, Ramos NC, Sinhoreti MAC, Borges ALS, Queiroz DA, Bottino MA. Fatigue Survival and Biomechanical Behavior of Two-piece Titanium and Zirconia Dental Implants. J Clin Exp Dent. 2026;18(5):e647-54.

 

doi:10.4317/jced.64022

https://doi.org/10.4317/jced.64022

___

 

References

1. Stimmelmayr M, Edelhoff D, Güth JF, Erdelt K, Happe A, Beuer F. Wear at the titanium titanium and the titanium zirconia implant abutment interface: a comparative in vitro study. Dent Mater. 2012;28(12):1215-1220.
https://doi.org/10.1016/j.dental.2012.08.008
PMid:23021964

 

2. Hanawa T. Zirconia versus titanium in dentistry: a review. Dent Mater. 2020;39(1):24-36.
https://doi.org/10.4012/dmj.2019-172
PMid:31666488

 

3. Vaghela H, Eaton K. Is zirconia a viable alternative to titanium for dental implantology? Eur J Prosthodont Restor Dent. 2022;30(1):1-13.
https://doi.org/10.1922/EJPRD_2166Vaghela13
PMid:33770424

 

4. Cao Y, Yu C, Wu Y, Li L, Li C. Long term survival and peri implant health of titanium implants with zirconia abutments: a systematic review and meta-analysis. J Prosthodont. 2019;28(8):883-892.
https://doi.org/10.1111/jopr.13097
PMid:31282107

 

5. Brånemark PI, Hansson BO, Adell R, Breine U, Lindström J, Hallén O, Ohman A. Osseointegrated implants in the treatment of the edentulous jaw. Experience from a 10 year period. Scand J Plast Reconstr Surg Suppl. 1977;16:1-132.

 

6. Sen N, Us YO. Fatigue survival and failure resistance of titanium versus zirconia implant abutments with various connection designs. J Prosthet Dent. 2019;122(3):315.e1-315.e7.
https://doi.org/10.1016/j.prosdent.2019.05.036
PMid:31326150

 

7. Sadowsky SJ. Has zirconia made a material difference in implant prosthodontics? A review. Dent Mater. 2020;36(1):1-8.
https://doi.org/10.1016/j.dental.2019.08.100
PMid:31500904

 

8. Piconi C, Maccauro G. Zirconia as a ceramic biomaterial. Biomaterials. 1999;20(1):1-25.
https://doi.org/10.1016/S0142-9612(98)00010-6
PMid:9916767 PMCid:PMC3548244

 

9. Bazal Bonelli S, Castro Janeiro M, Ríos Barbero J, Cano Sánchez de Tembleque M, López Quiles J, Meniz García C, et al. Clinical behavior of two piece zirconia implants: a systematic review. Med Oral Patol Oral Cir Bucal. 2025;30(3):e313-e321.
https://doi.org/10.4317/medoral.26752
PMid:40121684 PMCid:PMC12019655

 

10. Matos JD, Arcila LV, Ortiz LP, Lopes GR, Anami LC, Ramos NC, et al. Hybrid abutment during prosthetic planning and oral rehabilitation. Minerva Dent Oral Sci. 2022;71(2):107-116.
https://doi.org/10.23736/S2724-6329.21.04479-4
PMid:33929134

 

11. Ožiūnas R, Sakalauskienė J, Staišiūnas L, Žekonis G, Žilinskas J, Janužis G. Physical and mechanical changes on titanium base of three different types of hybrid abutment after cyclic loading. J Adv Prosthodont. 2023;15(1):33-43.
https://doi.org/10.4047/jap.2023.15.1.33
PMid:36908752 PMCid:PMC9992696

 

12. Hanes B, Feitosa S, Phasuk K, Levon JA, Morton D, Lin WS. Fracture resistance behaviors of titanium zirconium and zirconia implants. J Prosthodont. 2022;31(5):441-446.
https://doi.org/10.1111/jopr.13440
PMid:34632673

 

13. Osman RB, Swain MV, Atieh M, Ma S, Duncan W. Ceramic implants (Y TZP): are they a viable alternative to titanium implants for the support of overdentures? Clin Oral Implants Res. 2014;25(12):1366-1377.
https://doi.org/10.1111/clr.12272
PMid:24118368 PMCid:PMC11458096

 

14. Siddiqi A, Kieser JA, De Silva RK, Thomson WM, Duncan WJ. Soft and hard tissue response to zirconia versus titanium one piece implants placed in alveolar and palatal sites: a randomized controlled trial. Clin Implant Dent Relat Res. 2015;17(3):483-496.
https://doi.org/10.1111/cid.12159
PMid:24112624

 

15. Aragoneses J, Valverde NL, Fernandez Dominguez M, Mena Alvarez J, Rodriguez C, Gil J, et al. Relevant aspects of titanium and zirconia dental implants for their fatigue and osseointegration behaviors. Materials (Basel). 2022;15(11):4036.
https://doi.org/10.3390/ma15114036
PMid:35683331 PMCid:PMC9182570

 

16. Moreira A, Madeira S, Buciumeanu M, Fialho J, Carvalho A, Silva F, Monteiro FJ, Caramês J. Design and surface characterization of micropatterned silica coatings for zirconia dental implants. J Mech Behav Biomed Mater. 2022;126:105060.
https://doi.org/10.1016/j.jmbbm.2021.105060
PMid:34974323

 

17. Bormann KH, Gellrich NC, Kniha H, Schild S, Weingart D, Gahlert M. A prospective clinical study to evaluate the performance of zirconium dioxide dental implants in single tooth edentulous area: 3 year follow up. BMC Oral Health. 2018;18(1):181.
https://doi.org/10.1186/s12903-018-0636-x
PMid:30382850 PMCid:PMC6211599

 

18. Roehling S, Astasov Frauenhoffer M, Hauser Gerspach I, Braissant O, Woelfler H, Waltimo T, et al. In vitro biofilm formation on titanium and zirconia implant surfaces. J Periodontol. 2017;88(3):298-307.
https://doi.org/10.1902/jop.2016.160245
PMid:27712464

 

19. Chiou LL, Panariello BHD, Hamada Y, Gregory RL, Blanchard SB, Duarte S. Comparison of in vitro biofilm formation on titanium and zirconia implants. Biomed Res Int. 2023;15:8728499.
https://doi.org/10.1155/2023/8728499
PMid:37096222 PMCid:PMC10122594

 

20. Kohal RJ, Patzelt SB, Butz F, Sahlin H. One piece zirconia oral implants: one year results from a prospective case series. Part 2: Three unit fixed dental prosthesis reconstruction. J Clin Periodontol. 2013;40(5):553-562.
https://doi.org/10.1111/jcpe.12093
PMid:23506654

 

21. Freifrau von Maltzahn N, Bernard S, Kohorst P. Two part implant abutments with titanium and ceramic components: surface modification affects retention forces - an in vitro study. Clin Oral Implants Res. 2019;30(9):903-909.
https://doi.org/10.1111/clr.13495
PMid:31230382

 

22. Cionca N, Müller N, Mombelli A. Two piece zirconia implants supporting all ceramic crowns: a prospective clinical study. Clin Oral Implants Res. 2015;26(4):413-418.
https://doi.org/10.1111/clr.12370
PMid:24666352 PMCid:PMC4369135

 

23. Sivaraman K, Chopra A, Narayan AI, Balakrishnan D. Is zirconia a viable alternative to titanium for oral implant? A critical review. J Prosthodont Res. 2018;62(2):121-133.
https://doi.org/10.1016/j.jpor.2017.07.003
PMid:28827030

 

24. Rohr N, Brunner S, Märtin S, Fischer J. Influence of cement type and ceramic primer on retention of polymer infiltrated ceramic crowns to a one piece zirconia implant. J Prosthet Dent. 2018;119(1):138-145.
https://doi.org/10.1016/j.prosdent.2017.02.002
PMid:28461047

 

25. Zhang Y, Lawn BR. Novel zirconia materials in dentistry. J Dent Res. 2018;97(2):140-147.
https://doi.org/10.1177/0022034517737483
PMid:29035694 PMCid:PMC5784474

 

26. Tolentino L, Sukekava F, Garcez Filho J, Tormena M, Lima LA, Araújo MG. One year follow up of titanium/zirconium alloy versus commercially pure titanium narrow diameter implants placed in the molar region of the mandible: a randomized controlled trial. Clin Oral Implants Res. 2016;27(4):393-398.
https://doi.org/10.1111/clr.12561
PMid:25692479

 

27. Adolfi D, Tribst JPM, Adolfi M, Dal Piva AMO, Saavedra GSFA, Bottino MA. Lithium disilicate crown, zirconia hybrid abutment and platform switching to improve the esthetics in anterior region: a case report. Clin Cosmet Investig Dent. 2020;12:31-40.
https://doi.org/10.2147/CCIDE.S234980
PMid:32110113 PMCid:PMC7036665

 

28. Matos JDM, Lopes GDRS, Queiroz DA, Pereira ALJ, Sinhoreti MAC, Ramos NC, et al. Influence of the PEEK abutments on mechanical behavior of internal connection single implants. Materials (Basel). 2022;15(22):8133.
https://doi.org/10.3390/ma15228133
PMid:36431619 PMCid:PMC9696524

 

29. Matos JDM, Gomes LS, de Carvalho Ramos N, Queiroz DA, Tribst JPM, Campos TMB, et al. Influence of CAD/CAM abutment heights on the biomechanical behavior of zirconia single crowns. Metals. 2022;12(12):2025.
https://doi.org/10.3390/met12122025

 

30. Park JY, Jeong ID, Lee JJ, Bae SY, Kim JH, Kim WC. In vitro assessment of the marginal and internal fits of interim implant restorations fabricated with different methods. J Prosthet Dent. 2016;116(4):536-542.
https://doi.org/10.1016/j.prosdent.2016.03.012
PMid:27174406

 

31. Baladhandayutham B, Lawson NC, Burgess JO. Fracture load of ceramic restorations after fatigue loading. J Prosthet Dent. 2015;114(2):266-271.
https://doi.org/10.1016/j.prosdent.2015.03.006
PMid:25985741

 

32. Guilardi LF, Pereira G, Vallau AS, Silva IA, Giordani JC, Valandro LF, et al. Fatigue failure load of a bonded simplified monolithic feldspathic ceramic: influence of hydrofluoric acid etching and thermocycling. Oper Dent. 2020;45(1):E21-E31.
https://doi.org/10.2341/19-069-L
PMid:31794339

 

33. Bordin D, Cury AADB, Faot F. Influence of abutment collar height and implant length on stress distribution in single crowns. Braz Dent J. 2019;30(3):238-243.
https://doi.org/10.1590/0103-6440201902533
PMid:31166395

 

34. Wiskott HW, Belser UC. Lack of integration of smooth titanium surfaces: a working hypothesis based on strains generated in the surrounding bone. Clin Oral Implants Res. 1999;10(6):429-444.
https://doi.org/10.1034/j.1600-0501.1999.100601.x
PMid:10740452

 

35. International Organization for Standardization. Dentistry: dynamic fatigue test for endosseous dental implants. ISO 14801 3rd ed. Geneva: ISO. 2016; p. 1-10.

 

36. Edelhoff D, Schweiger J, Prandtner O, Stimmelmayr M, Güth JF. Metal free implant supported single tooth restorations. Part II: hybrid abutment crowns and material selection. Quintessence Int. 2019;50(4):260-269.

 

37. Payer M, Heschl A, Koller M, Arnetzl G, Lorenzoni M, Jakse N. All ceramic restoration of zirconia two piece implants - a randomized controlled clinical trial. Clin Oral Implants Res. 2015;26(4):371-376.
https://doi.org/10.1111/clr.12342
PMid:24502675

 

38. Martins JNR, Martins RF, Braz-Fernandes FM, Silva EJN L. What meaningful information are the instruments mechanical testing giving us? a comprehensive review. J Endod. 2022;48(8):985-1004.
https://doi.org/10.1016/j.joen.2022.05.007
PMid:35667567

 

39. Silva KRN, Joly JC, Peruzzo DC, Napimoga MH, Martinez EF. Influence of transmucosal height on loss of prosthetic abutment torque after mechanical cycling. J Oral Implantol. 2018;44(6):423-426.
https://doi.org/10.1563/aaid-joi-D-17-00250
PMid:30011229

 

40. Spazzin AO, Henrique GE, Nóbilo MA, Consani RL, Correr Sobrinho L, Mesquita MF. Effect of retorque on loosening torque of prosthetic screws under two levels of fit of implant-supported dentures. Braz Dent J. 2010;21(1):12-17.
https://doi.org/10.1590/S0103-64402010000100002
PMid:20464315

 

41. Cardoso M, Torres MF, Lourenço EJ, de Moraes Telles D, Rodrigues RC, Ribeiro RF. Torque removal evaluation of prosthetic screws after tightening and loosening cycles: an in vitro study. Clin Oral Implants Res. 2012;23(4):475-480.
https://doi.org/10.1111/j.1600-0501.2011.02165.x
PMid:21457352

 

42. Steiner M, Mitsias ME, Ludwig K, Kern M. In vitro evaluation of a mechanical chewing simulator. Dent Mater. 2009;25(4):494-499.
https://doi.org/10.1016/j.dental.2008.09.010
PMid:19036423

 

43. Conover WJ. Practical nonparametric statistics. 3rd ed. New York: John Wiley & Sons; 1999.

 

44. Datte CE, Tribst JPM, Dal Piva AMO, Nishioka RS, Bottino MA, Evan- gelhista ADM, Monteiro FMM, Borges ALS. Influence of different re- storative materials on the stress distribution in dental implants. J Clin Exp Dent. 2018;10(5):e439-44.
https://doi.org/10.4317/jced.54554
PMid:29849967 PMCid:PMC5971074