Gomes AL, Montero J. Zirconia implant abutments: A review. Med Oral Patol Oral Cir Bucal. 2011 Jan 1;16 (1):e50-5. 

 

doi:10.4317/medoral.16.e50

http://dx.doi.org/doi:10.4317/medoral.16.e50

 

 

1. Prestipino V, Ingber A. All-ceramic implant abutments: esthetic indications. J Esthet Dent. 1996;8:255-62.
doi:10.1111/j.1708-8240.1996.tb00876.x

2.
Aramouni P, Zebouni E, Tashkandi E, Dib S, Salameh Z, Almas K. Fracture resistance and failure location of zirconium and metallic implant abutments. J Contemp Dent Pract. 2008;9:41-8.
PMid:18997915

3. Att W, Kurun S, Gerds T, Strub JR. Fracture resistance of single-tooth implant-supported all-ceramic restorations: an in vitro study. J Prosthet Dent. 2006;95:111-6.
doi:10.1016/j.prosdent.2005.12.003
PMid:16473084

4. Yildirim M, Edelhoff D, Hanisch O, Spiekermann H. Ceramic abutments--a new era in achieving optimal esthetics in implant dentistry. Int J Periodontics Restorative Dent. 2000;20:81-91.
PMid:11203552

5. Andersson B, Schärer P, Simion M, Bergström C. Ceramic implant abutments used for short-span fixed partial dentures: a prospective 2-year multicenter study. Int J Prosthodont. 1999;12:318-24.
PMid:10635200

6. Andersson B, Glauser R, Maglione M, Taylor A. Ceramic implant abutments for short-span FPDs: a prospective 5-year multicenter study. Int J Prosthodont. 2003;16:640-6.
PMid:14714845

7. Yildirim M, Fischer H, Marx R, Edelhoff D. In vivo fracture resistance of implant-supported all-ceramic restorations. J Prosthet Dent. 2003;90:325-31.
doi:10.1016/S0022-3913(03)00514-6

8. Román-Rodríguez JL, Roig-Vanaclocha A, Fons-Font A, Granell-Ruiz M, Solá-Ruiz MF, Bruguera-Alvarez A. Full maxillary rehabilitation with an all-ceramic system.
Med Oral Patol Oral Cir Bucal. 2010;15:e523-5.
doi:10.4317/medoral.15.e523

9.
Kollar A, Huber S, Mericske E, Mericske-Stern R. Zirconia for teeth and implants: a case series. Int J Periodontics Restorative Dent. 2008;28:479-87.
PMid:18990999

10. Piconi C, Maccauro G. Zirconia as a ceramic biomaterial. Biomaterials. 1999;20:1-25.
doi:10.1016/S0142-9612(98)00010-6

11. Manicone PF, Rossi Iommetti P, Raffaelli L. An overview of zirconia ceramics: basic properties and clinical applications. J Dent. 2007;35:819-26.
doi:10.1016/j.jdent.2007.07.008
PMid:17825465

12. Garine WN, Funkenbusch PD, Ercoli C, Wodenscheck J, Murphy WC. Measurement of the rotational misfit and implant-abutment gap of all-ceramic abutments. Int J Oral Maxillofac Implants. 2007;22:928-38.
PMid:18271374

13. Vigolo P, Fonzi F, Majzoub Z, Cordioli G. An in vitro evaluation of titanium, zirconia, and alumina procera abutments with hexagonal connection. Int J Oral Maxillofac Implants. 2006;21:575-80.
PMid:16955608

14. Glauser R, Sailer I, Wohlwend A, Studer S, Schibli M, Schärer P. Experimental zirconia abutments for implant-supported single-tooth restorations in esthetically demanding regions: 4-year results of a prospective clinical study. Int J Prosthodont. 2004;17:285-90.
PMid:15237873

15. Adatia ND, Bayne SC, Cooper LF, Thompson JY. Fracture resistance of yttria-stabilized zirconia dental implant abutments. J Prosthodont. 2009;18:17-22.
doi:10.1111/j.1532-849X.2008.00378.x
PMid:19166544

16. Butz F, Heydecke G, Okutan M, Strub JR. Survival rate, fracture strength and failure mode of ceramic implant abutments after chewing simulation. J Oral Rehabil. 2005;32:838-43.
doi:10.1111/j.1365-2842.2005.01515.x
PMid:16202048

17. Sundh A, Sjögren G. A study of the bending resistance of implant-supported reinforced alumina and machined zirconia abutments and copies. Dent Mater. 2008;24:611-7.
doi:10.1016/j.dental.2007.05.021
PMid:17681595

18. Gehrke P, Dhom G, Brunner J, Wolf D, Degidi M, Piattelli A. Zirconium implant abutments: fracture strength and influence of cyclic loading on retaining-screw loosening. Quintessence Int. 2006;37:19-26.
PMid:16429699

19. Rimondini L, Cerroni L, Carrassi A, Torricelli P. Bacterial colonization of zirconia ceramic surfaces: an in vitro and in vivo study. Int J Oral Maxillofac Implants. 2002;17:793-8.
PMid:12507238

20. Scarano A, Piattelli M, Caputi S, Favero GA, Piattelli A. Bacterial adhesion on commercially pure titanium and zirconium oxide disks: an in vivo human study.
J Periodontol. 2004;75:292-6.
doi:10.1902/jop.2004.75.2.292
PMid:15068118